ESCA Software |
Acquisition of spectra :
1 - Up to 16 separate windows each containing :
- Name
- Excitation energy (Mg-Al-other)
- Start energy
- End energy
- Step
- Dwell time
- Pass energy
- Wait time (before starting acquisition)
- Modes :
- Continuous (oscilloscope type for adjustments)
- Multiple acquisitions (more acquisitions can be added if desired)
2 - X-ray gun control
- The X-ray source can be stopped at the end of the acquisitions
Spectra treatments :
1 - Visualization :
2 - Treatments :
- Display in increasing binding energy
- An unlimited number of spectra can be placed on screen
- Each spectrum can be zoomed in and out both in energy and in signal
- Smoothing (Fourier Transform)
- Spike removal (automatic or manual)
- Element identification
- Base line removal (linear or Shirley)
- Satellites removal
- Peak shape comparison
- Derivation
- Integration
- Peak fiiting (up to eight components single or double peaks)
- Peak width
- Quantification (manual or automatic)
3 - Files processing :
- Save as .txt files
- Print screen
| Auger Software |
Acquisition of spectra :
Up to 16 separate windows each containing :
- Name
- Beam energy
- Start energy
- End energy
- Step
- Dwell time or/and Scan speed
- Pass energy
- Point (when coupled with Imagum, the electron gun can be pointed at a pre-selected position)
- Wait time (before starting acquisition)
- Modes :
- Continuous (oscilloscope type for adjustments)
- Multiple acquisitions (more acquisitions can be added if desired)
Spectra treatments :
1 - Visualization :
2 - Treatments :
- Display in increasing binding energy
- An unlimited number of spectra can be placed on screen
- Each spectrum can be zoomed in and out both in energy and in signal
- Smoothing (Fourier Transform)
- Spike removal (automatic or manual)
- Element identification
- Derivation
- Integration
- Quantification (manual or automatic)
3 - Files processing :
- Save as .txt files
- Print screen
| Depth Profile Software |
Acquisition of depth profiles :
Up to 16 separate peaks each defined by :
- Name
- Beam energy
- Start energy
- End energy
- Step
- Dwell time or/and Scan speed
- Pass energy
- Sensitivity factor
- Point (when coupled with Imagum, the electron gun can be pointed at a pre-selected position)
- Wait time (before starting acquisition)
Spectra treatments :
1 - Visualization :
2 - Treatments :
- Display in time or depth
- An unlimited number of profiles can be placed on screen
- Each profile can be zoomed in and out both in energy and in signal
- Quantification with sensitivity factor
3 - Files processing :
- Save as .txt files
- Print screen